–
Energy Recovery Ventilator

4 products
| View | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| View | Panasonic Intelli-Balance 100 30-100 CFM (120V/60Hz/1Ø) - 4" duct | Panasonic | PAN-FV-10VE2H-4 | 6 year | MERV 8 filter included; MERV 8 (FV-FL0810VE1) and optional MERV 13 (FV FL1310VE1) replacements available. Unobtrusive alarm notifies owner for filter check and maintenance. | 4 | No | 23 gauge galvanized steel body. Four 4" or 6" intake and exhaust ducts. Built in damper on Outdoor Air (OA) closes during defrost function when the outdoor temperature is too cold. Filters on supply and exhaust air extend the life of the ERV core. (4) Pressure ports allow for easy airflow verification. Pre-drilled mounting bracket can accommodate 16", 19", or 24" on center. | ERV Supply and Exhaust ventilation rates shall be manually adjustable for 30-50-60-70-80-90-100 CFM. ERV shall have Hi/Lo Speed; Occupant Controlled Boost Capability up to 100 CFM. Two (2) enclosed DC brushless motors rated for continuous run. Power rating shall be 120 volts and 60 Hz. Motor equipped with thermal cut-off fuse control. Removable, permanently lubricated, plug-in motor | False | 3 year | FV | FV-10VE2H-4 | 1 | 60 | 8 85170 41647 5 | 120 | |
| View | Panasonic Intelli-Balance 100 30-100 CFM (120V/60Hz/1Ø) - 6" duct | Panasonic | PAN-FV-10VE2H-6 | 6 year | MERV 8 filter included; MERV 8 (FV-FL0810VE1) and optional MERV 13 (FV FL1310VE1) replacements available. Unobtrusive alarm notifies owner for filter check and maintenance. | 6 | No | 22 gauge galvanized steel body. Four 4" or 6" intake and exhaust ducts. Built in damper on Outdoor Air (OA) closes during defrost function when the outdoor temperature is too cold. Filters on supply and exhaust air extend the life of the ERV core. (4) Pressure ports allow for easy airflow verification. Pre-drilled mounting bracket can accommodate 16", 19", or 24" on center. | ERV Supply and Exhaust ventilation rates shall be manually adjustable for 30-50-60-70-80-90-100 CFM. ERV shall have Hi/Lo Speed; Occupant Controlled Boost Capability up to 100 CFM. Two (2) enclosed DC brushless motors rated for continuous run. Power rating shall be 120 volts and 60 Hz. Motor equipped with thermal cut-off fuse control. Removable, permanently lubricated, plug-in motor | False | 3 year | FV | FV-10VE2H-6 | 1 | 60 | 8 85170 41647 5 | 120 | |
| View | Panasonic Intelli-Balance 100 50-100 CFM (120V/60Hz/1Ø) - 4" duct | Panasonic | PAN-FV-10VE2-4 | 6-year | MERV 8 lter included; MERV 8 (FVFL0810VE1) and optional MERV 13 (FVFL1310VE1) replacements available. Unobtrusive alarm noti es owner for lter check and maintenance. | 4 | No | 22 gauge galvanized steel body. Four 4" or 6" intake and exhaust ducts. Built in dampers on exhaust and Outdoor Air ducts for defrost and recirculation cycling. Filters on supply and exhaust air extend the life of the ERV core. (4) Pressure ports allow for easy airflow veri cation. Pre-drilled mounting bracket can accommodate 16", 19", or 24" on center. | ERV shall have Hi/Lo Speed Occupant Controlled Boost Capability Two (2) enclosed DC brushless motors rated for continuous run. ERV Supply and Exhaust ventilation rates shall be manually adjustable for 50-60-70-80-90-100 CFM. Power rating shall be 120 volts and 60 Hz. Motor equipped with thermal cut-off fuse control. Removable, permanently lubricated, plug–in motor. | False | 3-year | FV | FV-10VE2-4 | 1 | 60 | 8 85170 37401 0 | 120 | |
| View | Panasonic Intelli-Balance 100 50-100 CFM (120V/60Hz/1Ø) - 6" duct | Panasonic | PAN-FV-10VE2-6 | 6-year | MERV 8 lter included; MERV 8 (FVFL0810VE1) and optional MERV 13 (FVFL1310VE1) replacements available. Unobtrusive alarm noti es owner for lter check and maintenance. | 6 | No | 22 gauge galvanized steel body. Four 4" or 6" intake and exhaust ducts. Built in dampers on exhaust and Outdoor Air ducts for defrost and recirculation cycling. Filters on supply and exhaust air extend the life of the ERV core. (4) Pressure ports allow for easy airflow veri cation. Pre-drilled mounting bracket can accommodate 16", 19", or 24" on center. | ERV shall have Hi/Lo Speed Occupant Controlled Boost Capability Two (2) enclosed DC brushless motors rated for continuous run. ERV Supply and Exhaust ventilation rates shall be manually adjustable for 50-60-70-80-90-100 CFM. Power rating shall be 120 volts and 60 Hz. Motor equipped with thermal cut-off fuse control. Removable, permanently lubricated, plug–in motor. | False | 3-year | FV | FV-10VE2-6 | 1 | 60 | 8 85170 37401 0 | 120 |
Showing 1 to 4 of 4 items
