Page 1 of 3
–
Schwank Outdoor Patio, Wet/Damp Env. Tube Heater

42 products
| View | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 110/75 MBH ; 30 FT; USA | Schwank | SCHW-SPW2-110-30-AL | JS-TW11-BL | 108/70,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. **Burner can be ordered LP. | 4" | No | LP** | **Burner can be order LP | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,003 | False | 30’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-110-30-AL | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 154 | TW-1430-JZ | - | 60" + 96" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 110/75 MBH ; 30 FT; USA SCHW-SPW2-110-30-AN | Schwank | SCHW-SPW2-110-30-AN | JS-TW11-BN | 110/80,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,002 | False | 30’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-110-30-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 154 | TW-1430-JZ | - | 60" + 96" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 110/75 MBH ; 40 FT; USA | Schwank | SCHW-SPW2-110-40-AN | JS-TW11-BN | 108/70,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,004 | False | 40’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-110-40-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 197 | TW-1040-JZ | - | 24" + 109" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 110/75 MBH ; 40 FT; USA SCHW-SPW2-110-40-AL | Schwank | SCHW-SPW2-110-40-AL | JS-TW11-BL | 108/70,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. **Burner can be ordered LP. | 4" | No | LP** | **Burner can be order LP | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,005 | False | 40’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-110-40-AL | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 197 | TW-1040-JZ | - | 24" + 109" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 130/90 MBH ; 30 FT; USA | Schwank | SCHW-SPW2-130-30-AN | JS-TW13-BN | 120/85,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. Natural gas only. | 4" | No | NG Only | Natural gas only | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,006 | False | 30’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-130-30-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 154 | TW-1430-JZ | - | 24" + 109" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 130/90 MBH ; 40 FT; USA | Schwank | SCHW-SPW2-130-40-AN | JS-TW13-BN | 120/85,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,007 | False | 40’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-130-40-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 197 | TW-1040-JZ | - | 60" + 96" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 155/110 MBH ; 40 FT; USA | Schwank | SCHW-SPW2-155-40-AN | JS-TW15-BN | 150/110,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,008 | False | 40’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-155-40-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 197 | TW-1040-JZ | - | 24" + 109" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 155/110 MBH ; 50 FT; USA | Schwank | SCHW-SPW2-155-50-AN | JS-TW15-BN | 150/110,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,009 | False | 50’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-155-50-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 239 | TW-F030-JZ | TW-0020-JZ | 24" (3rd tube) | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 175/125 MBH ; 50 FT; USA | Schwank | SCHW-SPW2-175-50-AN | JS-TW17-BN | 162/115,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. Natural gas only. | 4" | No | NG Only | Natural gas only | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,010 | False | 50’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-175-50-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 239 | TW-1030-JZ | TW-0020-JZ | 40" + 72" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 175/125 MBH ; 60 FT; USA | Schwank | SCHW-SPW2-175-60-AN | JS-TW17-BN | 162/115,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. Natural gas only. | 4" | No | NG Only | Natural gas only | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,011 | False | 60’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-175-60-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 282 | TW-1030-JZ | TW-0030-JZ | 40" + 72" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 200/140 MBH ; 50 FT; USA | Schwank | SCHW-SPW2-200-50-AN | JS-TW20-BN | 195/140,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. Natural gas only. | 4" | No | NG Only | Natural gas only | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,012 | False | 50’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-200-50-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 239 | TW-1030-JZ | TW-0020-JZ | 40" + 72" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 200/140 MBH ; 60 FT; USA | Schwank | SCHW-SPW2-200-60-AN | JS-TW20-BN | 195/140,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. Natural gas only. | 4" | No | NG Only | Natural gas only | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,013 | False | 60’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-200-60-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 282 | TW-1030-JZ | TW-0030-JZ | 72" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 80/60 MBH ; 20 FT; USA | Schwank | SCHW-SPW2-80-20-AN | JS-TW08-BN | 78/58,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,000 | False | 20’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-80-20-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 111 | TW-1420-JZ | - | 39" + 96" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | 2-Stage Wet/Outdoor Tube: Powder Coat Burner House + Alum'd Tube/Reflector; 80/60 MBH ; 30 FT; USA | Schwank | SCHW-SPW2-80-30-AN | JS-TW08-BN | 78/58,000 | UL Certification. ANSI Z83.26 / CSA 2.37 Standard for gas-fired Outdoor Infrared Patio Heaters. ANSI Z83.20 / CSA 2.34 Standard for Gas-Fired Low-Intensity Infrared Heaters. | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. *Field conversion kit required for LP fuel. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit. 1/2” X 24” 78,000 TO 120,000 AND 3/4” X 24” = 130,000 TO 195,001 | False | 30’ | Line Max: NG or LP 14" W.C. Line Min: 5" W.C NG 11" W.C LP | SPW2 | SPW2-80-30-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | — | Two-Stage | 154 | TW-1430-JZ | - | 96" | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh LP; 30 FT; USA | Schwank | SCHW-SPW-110-30-AL | JS-110W-BL | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | LP** | **Burner can be order LP | Flexible gas connector is included with each burner kit | False | 30’ | — | SPW | SPW-110-30-AL | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Burner can be ordered LP | Single-Stage | 154 | TW-1430-JZ | - | 13' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh LP; 40 FT; USA | Schwank | SCHW-SPW-110-40-AL | JS-110W-BL | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | LP** | **Burner can be order LP | Flexible gas connector is included with each burner kit | False | 40’ | — | SPW | SPW-110-40-AL | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Burner can be ordered LP | Single-Stage | 197 | TW-1040-JZ | - | 12' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh LP; 50 FT; USA | Schwank | SCHW-SPW-110-50-AL | JS-110W-BL | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | LP** | **Burner can be order LP | Flexible gas connector is included with each burner kit | False | 50’ | — | SPW | SPW-110-50-AL | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Burner can be ordered LP | Single-Stage | 239 | TW-F030-JZ | TW-0020-JZ | 2' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh NG; 30 FT; USA | Schwank | SCHW-SPW-110-30-AN | JS-110W-BN | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit | False | 30’ | — | SPW | SPW-110-30-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Field conversion kit required for LP fuel. | Single-Stage | 154 | TW-1430-JZ | - | 13' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh NG; 40 FT; USA | Schwank | SCHW-SPW-110-40-AN | JS-110W-BN | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit | False | 40’ | — | SPW | SPW-110-40-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Field conversion kit required for LP fuel. | Single-Stage | 197 | TW-1040-JZ | - | 12' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components | |
| View | duraSchwank Coated Burner Housing Tube Heater: 110,000 Btuh NG; 50 FT; USA | Schwank | SCHW-SPW-110-50-AN | JS-110W-BN | 110000 | UL Certification | Powder coated weather tight cabinet and aluminized steel reflectors and tubes. Fresh air adapter and cap for outside combustion air. Moisture resistant spark ignition package. Tough, durable finish. Whisper Quiet Ceramic Burner. Focus Shield reflector and end caps for premier IR heat output. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Flexible gas connector is included with each burner kit | False | 50’ | — | SPW | SPW-110-50-AN | Powder Coated Water Resistant. Complete with operation status indicator lights. Potted direct spark ignition. | Field conversion kit required for LP fuel. | Single-Stage | 239 | TW-F030-JZ | TW-0020-JZ | 2' | 120V (1Ø) | 10-year tube, 10-year burner cup, 3-year components |
Showing 1 to 20 of 42 items
