Page 1 of 3
–
Schwank Pos. Press. Series Gas Tube Heater

42 products
| View | ||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| View | builderSchwank Tube Heater: 100,000 Btuh NG; 20 FT; USA | Schwank | SCHW-S100-100-20-AN | indoor commercial and industrial applications | JS-E100-BN | 100000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG Only | Natural gas only. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 20’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S106 | S100-100-20-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 90 | 120/24VAC; 20VA | TM-1020-SX | - | Stamped S/S | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh LP; 30 FT; USA | Schwank | SCHW-S100-110-30-AL | indoor commercial and industrial applications | JS-E110-BL | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 30’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S107 | S100-110-30-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 120 | 120/24VAC; 20VA | TM-1430-SX | - | 60” + 96” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh LP; 40 FT; USA | Schwank | SCHW-S100-110-40-AL | indoor commercial and industrial applications | JS-E110-BL | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 40’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S109 | S100-110-40-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 150 | 120/24VAC; 20VA | TM-1040-SX | - | 24” + 109” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh LP; 50 FT; USA | Schwank | SCHW-S100-110-50-AL | indoor commercial and industrial applications | JS-E110-BL | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S111 | S100-110-50-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-F030-SX | TM-0020-SX | 24” (3rd Tube) | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh NG; 30 FT; USA | Schwank | SCHW-S100-110-30-AN | indoor commercial and industrial applications | JS-E110-BN | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 30’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S108 | S100-110-30-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 120 | 120/24VAC; 20VA | TM-1430-SX | - | 60” + 96” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh NG; 40 FT; USA | Schwank | SCHW-S100-110-40-AN | indoor commercial and industrial applications | JS-E110-BN | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 40’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S110 | S100-110-40-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 150 | 120/24VAC; 20VA | TM-1040-SX | - | 24” + 109” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 110,000 Btuh NG; 50 FT; USA | Schwank | SCHW-S100-110-50-AN | indoor commercial and industrial applications | JS-E110-BN | 110000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S112 | S100-110-50-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-F030-SX | TM-0020-SX | 24” (3rd Tube) | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 130,000 Btuh NG; 30 FT; USA | Schwank | SCHW-S100-130-30-AN | indoor commercial and industrial applications | JS-E130-BN | 125000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG Only | Natural gas only. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 30’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S113 | S100-130-30-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 120 | 120/24VAC; 20VA | TM-1430-SX | - | 60” + 96” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 130,000 Btuh NG; 40 FT; USA | Schwank | SCHW-S100-130-40-AN | indoor commercial and industrial applications | JS-E130-BN | 125000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 40’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S114 | S100-130-40-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 150 | 120/24VAC; 20VA | TM-1040-SX | - | 24” + 109” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 130,000 Btuh NG; 50 FT; USA | Schwank | SCHW-S100-130-50-AN | indoor commercial and industrial applications | JS-E130-BN | 125000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S115 | S100-130-50-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-F030-SX | TM-0020-SX | 24” (3rd Tube) | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 155,000 Btuh NG; 40 FT; USA | Schwank | SCHW-S100-155-40-AN | indoor commercial and industrial applications | JS-E155-BN | 150000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 40’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S116 | S100-155-40-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 150 | 120/24VAC; 20VA | TM-1040-SX | - | 24” + 109” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 155,000 Btuh NG; 50 FT; USA | Schwank | SCHW-S100-155-50-AN | indoor commercial and industrial applications | JS-E155-BN | 150000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S117 | S100-155-50-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-F030-SX | TM-0020-SX | 24” (3rd Tube) | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 155,000 Btuh NG; 60 FT; USA | Schwank | SCHW-S100-155-60-AN | indoor commercial and industrial applications | JS-E155-BN | 150000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 60’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S118 | S100-155-60-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 210 | 120/24VAC; 20VA | TM-F030-SX | TM-0030-SX | 24” (3rd Tube) | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 175,000 Btuh LP; 50 FT; USA | Schwank | SCHW-S100-175-50-AL | indoor commercial and industrial applications | JS-E175-BL | 175000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S119 | S100-175-50-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 210 | 120/24VAC; 20VA | TM-1030-SX | TM-0020-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 175,000 Btuh LP; 60 FT; USA | Schwank | SCHW-S100-175-60-AL | indoor commercial and industrial applications | JS-E175-BL | 175000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 60’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S121 | S100-175-60-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-1030-SX | TM-0030-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 175,000 Btuh NG; 50 FT; USA | Schwank | SCHW-S100-175-50-AN | indoor commercial and industrial applications | JS-E175-BN | 175000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 50’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S120 | S100-175-50-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 180 | 120/24VAC; 20VA | TM-1030-SX | TM-0020-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 175,000 Btuh NG; 60 FT; USA | Schwank | SCHW-S100-175-60-AN | indoor commercial and industrial applications | JS-E175-BN | 175000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG* | *Field conversion kit required for LP fuel. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 60’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S122 | S100-175-60-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 210 | 120/24VAC; 20VA | TM-1030-SX | TM-0030-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 175,000 Btuh NG; 70 FT; USA | Schwank | SCHW-S100-175-70-AN | indoor commercial and industrial applications | JS-E175-BN | 175000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 4" | No | NG Only | Natural gas only. | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 70’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S123 | S100-175-70-AN | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 240 | 120/24VAC; 20VA | TM-1030-SX | TM-0040-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 200,000 Btuh LP; 60 FT; USA | Schwank | SCHW-S100-200-60-AL | indoor commercial and industrial applications | JS-E200-BL | 200000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 5" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 60’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S125 | S100-200-60-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 210 | 120/24VAC; 20VA | TM-1030-SX | TM-0030-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. | |
| View | builderSchwank Tube Heater: 200,000 Btuh LP; 70 FT; USA | Schwank | SCHW-S100-200-70-AL | indoor commercial and industrial applications | JS-E200-BL | 200000 | UL Certification. | All burner assemblied powered by hard wired 120V line voltage. Wire hangers allow flecible positioning along the system. Birdscreened combustion air collar, 4" to allow for sealed combustion. Flexible gas connector included. | 5" | No | LP ** | **Burner can be order LP | Honeywell 24 Volt. Natural Gas: 3 1/2” W.C. Manifold Propane: 10” W.C. Manifold. | False | 70’ | Line minimum: 5" W.C NG 11" W.C LP Line Maximum: NG or LP 14" W.C | S127 | S100-200-70-AL | Housing: The clam shell, provides access from the 2 sides, end, and bottom. Head: Incorporates effective ceramic burner head with minimum 835 flame ports. | Single-Stage | 240 | 120/24VAC; 20VA | TM-1030-SX | TM-0040-SX | 40” + 72” | — | 5-year tube & burner cup, 2-year components. |
Showing 1 to 20 of 42 items